I-10℃ Transformer oil

•Superior dielectric strength ensures reliable insulation and electrical safety.
•Excellent thermal stability maintains optimal performance under extreme temperatures.
•Advanced oxidation resistance extends service life and reduces maintenance needs.
•Environmentally friendly

Have a Question? Ask a Specialist

(+86) 13186966668 Start Live Chat

Competitive Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

Technical Expertise

We know our products

Warranty

1-year Warranty

Description

General


Transformer oil or insulating oil is an oil that is stable at high temperatures and has excellent electrical insulating properties. Transformer oil is a specially refined high-performance fluid designed for the safe and efficient operation of oil-immersed electrical equipment, including power transformers, instrument transformers, oil-filled bushings, and oil circuit breakers. As an indispensable core component in power transmission and distribution systems, it integrates multiple key functions to protect electrical equipment, extend service life, and ensure stable power supply, playing an irreplaceable role in modern power grids worldwide.

Product:I-10℃Transformer Oil LOT NO:1#
Date:2026 Standard:GB2536-2011
Items No. Test Items Test index Test Results Test Method
1 LCSET -10℃
2 Pour Point/℃ <-20 -33 GB/T3535-2006
3 Kinematic Viscosity/(mm²/s) 40℃ <12 10.23 GB/T265-1988
                    -20℃ <1800 655.73
4 Water Content/(㎎/㎏) <30 18 GB/T7600-2014
5 Breakdown Voltage*/KV >30 61 GB/T507-2002
6 Density@20℃/(㎏/m³) <895 875 GB/T1884-2000
7 Flash Point/℃ Report 79.1 GB/T262-2010
8 Dielectric Dissipation Factor(90℃) <0.005 0.0003 GB/T5654-2007
9 Appearance Clear、Precipitate-free、Suspended Solids free Clear、Precipitate-free、Suspended Solids free visualization
10 Neutralization number/(㎎/g) <0.01 0.006 NB/SH/T0836-2010
11 water soluble acid/alkali non non GB/T259-1988
12 Interfacial tension/(mN/m) >40 43 GB/T6541-1986
13 Total sulphur Content/% <0.15 0.003 SH/T0689-2000
14 Corrosive sulfur* noncorrosive noncorrosive SH/T0804-2007
15 Oxidation inhibitor content*/% 0.08-0.4 0.13 SH/T0802-2007
16 2-FAL Content/(㎎/㎏) <0.05 0.015 NB/SH/T0812-2010
17 Oxidation stability(120℃  500h)
Total Acid Number(TAN)/(㎎/g)
Plastocene/%
Dissipation Factor(90℃)
<0.3
<0.05
<0.050
0.03
0.016
0.008
NB/SH/T0811-2010
GB/T5654-2007
18 degassing of insulating oil/(mm³/min) Report +23.1 NB/SH/T0811-2010
19 ECT /(uC/m³) Report 1 DL/T385-2010
20 Flash Point /℃ >135 142 GB/T261-2008
21 PCAs Content /% <3 <2 NB/SH/T0838-2010
22 PCBs Content /% <2 0 SH/T0803-2007

 

Product Overview


Our transformer oil is meticulously processed to meet strict international standards, including IEC 60296, ASTM D 3487, and GB 2536-2026. It is available in multiple formulations tailored to different application scenarios and climatic conditions, primarily classified into four categories based on base oil sources, each with unique characteristics to meet diverse customer needs.

Product Types & Key Features


 Mineral-Based Transformer Oil which derived from refined petroleum fractions (mainly naphthenic and paraffinic crude oil), this type is the most widely used transformer oil with a history of nearly a century. It features excellent dielectric properties, cost-effectiveness, and mature production technology, making it the ideal choice for ultra-high voltage and extra-high voltage power transformers. Our mineral-based transformer oil adopts advanced hydrogenation technology, which significantly improves oxidation stability, extends service life, and reduces sludge formation compared to traditional refining processes. It has a relative density of approximately 0.895, a freezing point below -45℃, and a flash point above 140℃, ensuring stable performance in most climatic environments.

Core Functions


  • Insulation Protection: With a dielectric constant of 2.25 (compared to 1.0 for air), transformer oil provides excellent electrical insulation, preventing short circuits and arcing between live components (windings, core, and tank). It penetrates into the gaps of fiber insulation materials, enhancing overall insulation strength and protecting equipment from electrical breakdown under long-term operating voltage and impact voltage.
  • Heat Dissipation & Cooling: Transformer oil has a high specific heat capacity (approximately 0.5 cal/g·℃) and good thermal conductivity. It absorbs heat generated by copper loss and iron loss during transformer operation, circulates through natural convection or forced cooling (fans, oil pumps), and dissipates heat through radiators, ensuring the equipment operates within the optimal temperature range.
  • Arc Extinguishing: In oil circuit breakers and on-load tap changers, it effectively extinguishes electric arcs generated during switching operations, reducing wear on contacts and protecting equipment from damage.
  • Component Protection: It isolates the transformer’s core, windings, and other components from air and moisture, preventing rust and moisture erosion. Additionally, it minimizes the oxidation of cellulose insulation materials, extending the service life of both the oil and the equipment.
  • Condition Monitoring: As an information carrier, the oil’s physical and chemical properties (such as acid value, viscosity, and breakdown voltage) change with equipment degradation, enabling real-time monitoring of transformer health through oil testing.

Technical Advantages


  • Strict Quality Control: Our transformer oil undergoes rigorous testing throughout the production process, ensuring low impurity content (no PCBs), stable dielectric properties, and compliance with international standards.
  • Wide Temperature Adaptability: With pour points ranging from -10℃ to -55℃ (for different grades), it maintains fluidity and performance in both high-temperature and extremely cold regions (e.g., -45℃ for grade 45).
  • Long Service Life: Advanced refining and additive technologies reduce oxidation and sludge formation, extending the oil’s service life and reducing maintenance costs for customers.
  • Environmentally Friendly Options: Our vegetable-based and synthetic ester transformer oils meet global environmental standards, supporting green energy development and reducing environmental impact in case of leakage.

Application Scenarios


Our transformer oil is widely used in various fields of power transmission and distribution, including:
  • Power Transformers: Used in power generation plants, substations, and grid transmission systems (330kV and below for standard grades, ultra-high voltage for specialized grades).
  • Distribution Transformers: Applied in urban and rural distribution networks, industrial parks, and commercial buildings to ensure stable power supply to end users.
  • Specialized Equipment: Suitable for instrument transformers, oil-filled bushings, oil circuit breakers, and transformers in renewable energy projects (wind farms, solar power plants) and railway systems.
  • Harsh Environments: Customized formulations for extreme cold, high temperature, and environmentally sensitive areas (e.g., offshore, forests, and residential zones).

Quality Commitment


We adhere to the principle of “quality first, customer-centric” and continuously optimize our production processes and product formulations. All our transformer oil products are accompanied by detailed test reports and comply with global environmental and safety standards. We also provide professional technical support and after-sales service, helping customers select the most suitable product and ensuring the safe and efficient operation of their electrical equipment.
With over a century of industry evolution, transformer oil has developed into a multi-functional, high-performance fluid that underpins the stability of modern power grids. Our diverse product range and strict quality control make us a reliable partner for power companies, industrial enterprises, and infrastructure projects worldwide.

 

Reviews

There are no reviews yet.

Be the first to review “I-10℃ Transformer oil”

Your email address will not be published. Required fields are marked *